Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 926
Filtrar
1.
JAMA Netw Open ; 7(4): e244592, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38602679

RESUMO

Importance: Changes in cervical length in twin pregnancies exhibit various patterns, but it is unclear whether the mechanism underlying spontaneous preterm birth (sPTB) is consistent. The existence of detailed phenomena in singleton pregnancies is also unclear. Objectives: To explore the different patterns in cervical length trajectories in singleton and twin pregnancies and to analyze whether the immunological mechanisms of sPTB are consistent among these cervical length patterns. Design, Setting, and Participants: This cohort study recruited pregnant individuals who received antenatal care and delivered at Peking University Third Hospital in Beijing, China, between January 1, 2014, and December 31, 2022. Individuals with singleton and twin pregnancies were included. Exposures: Cervical length measurements and white blood cell (WBC) indicators. Main Outcomes and Measures: The primary outcome was sPTB. Longitudinal trajectory cluster analysis was used to identify patterns of changes in cervical length in singleton and twin pregnancies. A random-effects model with cubic spline was used to fit and compare the longitudinal trajectory of WBC indicators among early preterm birth, moderate to late preterm birth, and term birth. Results: A total of 43 559 pregnant individuals were included; of these, 41 706 had singleton pregnancies (mean [SD)] maternal age, 33.0 [4.0] years) and 1853 had twin pregnancies (mean [SD] maternal age, 33.3 [3.6] years). Two distinct patterns of cervical length changes were observed in both singleton and twin pregnancies: shortened (21 366 singletons and 546 twins) and stable (20 340 singletons and 1307 twins). In singleton pregnancies, WBC count was associated with early sPTB in individuals with both shortened cervix (odds ratio [OR], 1.35; 95% CI, 1.00-1.82) and stable cervix (OR, 1.64; 95% CI, 1.07-2.50). However, for twin pregnancies, the association of WBC count (OR, 3.13; 95% CI, 1.58-6.18) with the risk of early sPTB was observed only in individuals with a shortened cervix. Conclusions and Relevance: This study identified 2 distinct cervical length patterns: shortened and stable. These patterns revealed 2 preterm birth mechanisms in twin pregnancies, with the immunopathogenesis of sPTB found only in the shortened cervix pattern; in singleton pregnancies, maternal immune response was associated with a higher risk of sPTB regardless of a shortened or stable cervix.


Assuntos
Gravidez de Gêmeos , Nascimento Prematuro , Recém-Nascido , Gravidez , Humanos , Feminino , Adulto , Medida do Comprimento Cervical , Estudos de Coortes , Nascimento Prematuro/epidemiologia , China/epidemiologia
2.
Am J Obstet Gynecol MFM ; 6(5S): 101313, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38387505

RESUMO

BACKGROUND: National second-trimester scanning of cervical length was introduced in Israel in 2010, and in the decade thereafter, a significant systematic reduction in preterm birth and in the delivery of low birthweight babies was found among singletons. OBJECTIVE: In this study, we sought to estimate the cost-effectiveness of a national policy mandating second-trimester cervical length screening by ultrasound, followed by vaginal progesterone treatment for short cervical length in comparison with no screening strategy. STUDY DESIGN: We constructed a decision model comparing 2 strategies, namely (1) universal cervical length screening, and (2) no screening strategy. This study used the national delivery registry of Israel's Ministry of Health. All women diagnosed with a second-trimester cervical length <25 mm were treated with vaginal progesterone and were monitored with a bimonthly ultrasound scan for cervical dynamics and threat of early delivery. Preterm birth prevalence associated with short cervical length, the efficacy of progesterone in preterm birth prevention, and the accuracy of cervical length measurements were derived from previous studies. The cost of progesterone and bimonthly sonographic surveillance, low birthweight delivery, newborn admission to intensive care units, the first-year costs of managing preterm birth and low birthweight, and instances of handicaps and the cost of their follow-up were extracted from the publicly posted registry of Israel's Ministry of Health and Israel Social Securities data. Monte Carlo simulations decision tree mode, Tornado diagrams, and 1- and 2-way sensitivity analyses were implemented and the base case and sensitivity to parameters that were predicted to influence cost-effectiveness were calculated. RESULTS: Without cervical length screening, the discounted quality-adjusted life years were 30.179, and with universal cervical length screening, it increased to 30.198 (difference of 0.018 quality-adjusted life years). The average cost of no screening for cervical length strategy was $1047, and for universal cervical length screening, it was reduced to $998. The calculated incremental cost-effectiveness ratio was -$2676 per quality-adjusted life year (dividing the difference in costs by the difference in quality-adjusted life years). Monte Carlo simulation of cervical length screening of 170,000 singleton newborns (rounded large number close to the number of singleton newborns in Israel) showed that 95.17% of all babies were delivered at gestational week ≥37 in comparison with 94.46% of babies with the no screening strategy. Given 170,000 singleton births, the national savings of screening for short cervical length when compared with no cervical length screening amounted to $8.31M annually, equating to $48.84 for a base case, and the incremental cost-effectiveness ratio for each case of low birthweight or very low birthweight avoided was -$14,718. A cervical length <25 mm was measured for 30,090 women, and of those, 24,650 were false positives. The major parameters that affected the incremental cost-effectiveness ratio were the incidence of preterm birth, the specificity of cervical length measurements, and the efficacy of progesterone treatment. At a preterm birth incidence of <3%, universal screening does not lead to a cost saving. CONCLUSION: National universal cervical length screening should be incorporated into the routine anomaly scan in the second trimester, because it leads to a drop in the incidence of preterm birth and low birthweight babies in singleton pregnancies, thereby saving costs related to the newborn and gaining quality-adjusted life years.


Assuntos
Nascimento Prematuro , Progesterona , Gravidez , Recém-Nascido , Feminino , Humanos , Nascimento Prematuro/diagnóstico , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/prevenção & controle , Análise Custo-Benefício , Medida do Comprimento Cervical , Peso ao Nascer
3.
Am J Obstet Gynecol MFM ; 6(3): 101298, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38278178

RESUMO

BACKGROUND: A previous term (≥37 weeks' gestation), full-dilatation cesarean delivery is associated with an increased risk for a subsequent spontaneous preterm birth. The mechanism is unknown. We hypothesized that the cesarean delivery scar characteristics and scar position relative to the internal cervical os may compromise cervical function, thereby leading to shortening of the cervical length and spontaneous preterm birth. OBJECTIVE: This study aimed to determine the relationship of cesarean delivery scar characteristics and position, assessed by transvaginal ultrasound, in pregnant women with previous full-dilatation cesarean delivery with the risk of shortening cervical length and spontaneous preterm birth. STUDY DESIGN: This was a single-center, prospective cohort study of singleton pregnant women (14 to 24 weeks' gestation) with a previous term full-dilatation cesarean delivery who attended a high-risk preterm birth surveillance clinic (2017-2021). Women underwent transvaginal ultrasound assessment of cervical length, cesarean delivery scar distance relative to the internal cervical os, and scar niche parameters using a reproducible transvaginal ultrasound technique. Spontaneous preterm birth prophylactic interventions (vaginal cervical cerclage or vaginal progesterone) were offered for short cervical length (≤25 mm) and to women with a history of spontaneous preterm birth or late miscarriage after full-dilatation cesarean delivery. The primary outcome was spontaneous preterm birth; secondary outcomes included short cervical length and a need for prophylactic interventions. A multivariable logistic regression analysis was used to develop multiparameter models that combined cesarean delivery scar parameters, cervical length, history of full-dilatation cesarean delivery, and maternal characteristics. The predictive performance of models was examined using the area under the receiver operating characteristics curve and the detection rate at various fixed false positive rates. The optimal cutoff for cesarean delivery scar distance to best predict a short cervical length and spontaneous preterm birth was analyzed. RESULTS: Cesarean delivery scars were visualized in 90.5% (220/243) of the included women. The spontaneous preterm birth rate was 4.1% (10/243), and 12.8% (31/243) of women developed a short cervical length. A history- (n=4) or ultrasound-indicated (n=19) cervical cerclage was performed in 23 of 243 (9.5%) women; among those, 2 (8.7%) spontaneously delivered prematurely. A multiparameter model based on absolute scar distance from the internal os best predicted spontaneous preterm birth (area under the receiver operating characteristics curve, 0.73; 95% confidence interval, 0.57-0.89; detection rate of 60% for a fixed 25% false positive rate). Models based on the relative anatomic position of the cesarean delivery scar to the internal os and the cesarean delivery scar position with niche parameters (length, depth, and width) best predicted the development of a short cervical length (area under the receiver operating characteristics curve, 0.79 [95% confidence interval, 0.71-0.87]; and 0.81 [95% confidence interval, 0.73-0.89], respectively; detection rate of 73% at a fixed 25% false positive rate). Spontaneous preterm birth was significantly more likely when the cesarean delivery scar was <5.0 mm above or below the internal os (adjusted odds ratio, 6.87; 95% confidence interval, 1.34-58; P =.035). CONCLUSION: In pregnancies following a full-dilatation cesarean delivery, cesarean delivery scar characteristics and distance from the internal os identified women who were at risk for spontaneous preterm birth and developing short cervical length. Overall, the spontaneous preterm birth rate was low, but it was significantly increased among women with a scar located <5.0 mm above or below the internal cervical os. Shortening of cervical length was strongly associated with a low scar position. Our novel findings indicate that a low cesarean delivery scar can compromise the functional integrity of the internal cervical os, leading to cervical shortening and/or spontaneous preterm birth. Assessment of the cesarean delivery scar characteristics and position seem to have use in preterm birth clinical surveillance among women with a previous, full-dilatation cesarean delivery and could better identify women who would benefit from prophylactic interventions.


Assuntos
Nascimento Prematuro , Recém-Nascido , Gravidez , Feminino , Humanos , Masculino , Nascimento Prematuro/diagnóstico , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/etiologia , Estudos Prospectivos , Cicatriz/etiologia , Cicatriz/complicações , Dilatação/efeitos adversos , Medida do Comprimento Cervical/efeitos adversos , Medida do Comprimento Cervical/métodos
4.
J Obstet Gynaecol Res ; 50(1): 47-54, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37916525

RESUMO

AIM: This study aimed to evaluate the effect of preinduction cervical length (CL) measurement by transvaginal (TV), transperineal (TP), and transabdominal (TA) ultrasonography (USG) on the time of delivery and to compare these three sonographic methods in terms of superiority over one another. METHODS: This study included TV, TP, and TA CL measurements in pregnant women who were planned to undergo induction of labor at 37 weeks' gestation or later. The correlations between the said three methods and BISHOP scores were evaluated. These three methods were compared in terms of superiority in predicting the time of delivery. RESULTS: Pregnant women at 37-42 weeks' gestation undergoing labor induction were included, and all three methods were used for CL measurements. Three methods were correlated with each other (p < 0.001) and with BISHOP scores (p < 0.001). CONCLUSION: The correlation between all three methods and BISHOP scores indicates that TP and TA USG can be used instead of TV USG. On the other hand, while TA USG did not give a clear result in the accurate estimation of vaginal delivery time, TP, and TV USG gave both accurate and close results. When all these data are evaluated, it is concluded that TPU can be used safely instead of TVU, especially in patients receiving induction.


Assuntos
Medida do Comprimento Cervical , Colo do Útero , Gravidez , Feminino , Humanos , Medida do Comprimento Cervical/métodos , Colo do Útero/diagnóstico por imagem , Parto Obstétrico/métodos , Vagina/diagnóstico por imagem , Idade Gestacional , Trabalho de Parto Induzido , Valor Preditivo dos Testes
5.
J Obstet Gynaecol Res ; 50(1): 65-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37903492

RESUMO

OBJECTIVES: The aim of this study was to evaluate the relationship between the cervix and the threat of preterm labor in singleton pregnancies between gestational weeks less than 37 and greater than 37 weeks in correlation with utero-cervical angle (UCA) and cervical length (CL) measurements. MATERIALS AND METHODS: We conducted a prospective cohort study with UCA and CL measurements in patients with threatened preterm labor (TPL). Primary outcome was differences in UCA and CL measurements in relationship to maternal characteristics and perinatal outcome between groups. Secondary outcome evaluated measurement results and influencing factors for delivery within 7 days, between 1 and 4 weeks and beyond 4 weeks. RESULTS: Overall 152 patients were divided into as study/preterm group (<37 weeks; n = 56) and the control/term group (≥37 weeks; n = 96). Mean gestational age at admission was similar in both groups (30.98 ± 2.83 vs. 30.36 ± 2.63 weeks, p = 0.149) with similar CL (33.9 ± 6.34 vs. 32.02 ± 8.88 mm, p = 0.132), but wider UCA in the preterm group (81.65 ± 16.81° vs. 99.21 ± 22.33°, p < 0.001). Multivariate logistic regression analysis for preterm delivery was significant for nulliparity and UCA measurement. The factor for delivering before 37 gestational weeks within 7 days was the gestational week at admission (p = 0.046). UCA and CL measurements were statistically significant for distinguishing patients for delivery within 7 days and beyond 4 weeks (p = 0.001 for CL and p = 0.0001 for UCA). NPV was found 92.5, 92.2, and 92.3 for UCA >105°, CL ≤30 mm, and Bishop score >3, respectively. CONCLUSION: Combined measurement of TV UCA and CL represents stronger predictors for sPTB ultrasonographically, demonstrating the uterocervical sub-segment maturation before the active onset of labor.


Assuntos
Trabalho de Parto Prematuro , Nascimento Prematuro , Gravidez , Feminino , Recém-Nascido , Humanos , Colo do Útero/diagnóstico por imagem , Estudos Prospectivos , Trabalho de Parto Prematuro/diagnóstico por imagem , Útero , Medida do Comprimento Cervical/métodos
6.
J Perinat Med ; 52(1): 76-80, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37942777

RESUMO

OBJECTIVES: To compare transvaginal (TV) and trans-abdominal (TA) ultrasound assessment of cervical length (CL) at the time of the second-trimester scan for fetal anomalies. METHODS: This was a prospective study including consecutive pregnant women attending the low-risk ultrasound clinic of two fetal medicine centres in Italy. The inclusion criteria were women between 19 + 0 and 22 + 0 weeks of gestation, attending the prenatal ultrasound clinic for the routine second trimester screening for fetal anomalies. The primary outcome was to compare the CL measurement obtained at TV compared to TA ultrasound; the secondary outcome was to report the inter and intra-observer variability of CL measured with the two different approaches. All women underwent TV and TA assessment of the cervix performed by two experienced certified operators, blinded to each other. Intra-class correlation coefficients (ICC) and Bland-Altman analyses were used to analyse the data. RESULTS: Two hundred and fifty women were included in the analysis. All women had anteverted uterus. The mean gestational age at ultrasound was 20.7 ± 0.7 weeks; 1.2 % (3/250) scans were performed at 19 weeks, 49.2 % (123/250) at 20 weeks, 44.8 % (112/250) at 21 weeks and 4.8 % (12/250) at 22 weeks of gestations. Identification of the major landmarks of CL at TA ultrasound was achieved in all the included cases. There was good reliability between CL measured at TA (ICC 0.95, 95 % CI 0.93-0.97 for observer 1 and 0.92 %, 95 % CI 0.89-0.94 for observer 2) and TV ultrasound 0.97, 95 % CI 0.96-0.98 for observer 1 and 0.96, 95 % CI 0.95-0.97 for observer 2). There was also good reliability between the two observers for both the TA and TV assessment of the CL. Mean TA CL was 41.4 ± 5.5 for observer 1 and 40.5 ± 4.8 for observer 2 with no significant differences between the two measurements (mean difference 0.92 mm, 95 % CI -9.7 to 11.2). Likewise, there was no difference between the CL measured at TV ultrasound between the two observers (mean difference -0.83 mm, 95 % CI -5.97 to 4.30). Finally, there was no difference in the mean CL measured at TA compared to TV, either considering the overall population of women (mean difference: -0.43, 955 CI -8.65 to 7.79), or when stratifying the analysis according to the parity status and the operator. CONCLUSIONS: Among experienced operators, there was no difference between TV and TA ultrasound assessment of the CL at the time of the routine anomaly scan for fetal anomaly.


Assuntos
Medida do Comprimento Cervical , Colo do Útero , Gravidez , Feminino , Humanos , Lactente , Masculino , Segundo Trimestre da Gravidez , Colo do Útero/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia , Ultrassonografia Pré-Natal
7.
Int J Gynaecol Obstet ; 164(3): 951-958, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37675927

RESUMO

OBJECTIVE: To assess the impact of the introduction of universal transvaginal cervical screening and certification on the quality of cervical length ultrasound images. METHODS: The present study included a retrospective cohort of singleton pregnancies that underwent transvaginal cervical length measurement at the anatomical scan (180/7 and 236/7 weeks) before (period A, 2015-2017) and after (period B, 2017-2019) the introduction of universal transvaginal cervical length screening. Independent observers blindly evaluated the images obtained for cervical length using a qualitative scoring method based on five criteria, according to the Fetal Medicine Foundation. RESULTS: In all, 6013 patients met the inclusion criteria, 3333 in period A and 2680 in period B. Maternal characteristics and risk factors for preterm birth were similar between the two periods. The acceptance of transvaginal cervical length measurement in period B was 95.5% in the overall cohort and 100% in the subgroup of high-risk patients. The quality score was significantly higher in period B than in period A. Among the image quality criteria, the anterior/posterior ratio, the correct magnification of the images, and the calipers' placement contributed significantly to the improved quality score in period B. Most of the sonographers performed better in period B, irrespective of the years of experience, but certificate holders obtained higher scores than non-certified sonographers, particularly those in mid-career. The identification of short cervix was significantly higher in period B than in period A. CONCLUSION: The implementation of universal transvaginal cervical length screening and the certification process are associated with improved quality of cervical length images, even among expert sonographers and in the presence of anatomical pitfalls.


Assuntos
Nascimento Prematuro , Neoplasias do Colo do Útero , Gravidez , Feminino , Humanos , Recém-Nascido , Nascimento Prematuro/prevenção & controle , Colo do Útero/diagnóstico por imagem , Estudos Retrospectivos , Detecção Precoce de Câncer , Neoplasias do Colo do Útero/diagnóstico por imagem , Medida do Comprimento Cervical/métodos , Certificação
10.
Arch Gynecol Obstet ; 309(1): 175-181, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-36697853

RESUMO

PURPOSE: To evaluate patients' acceptance of a universal transvaginal ultrasound cervical length (CL) screening program and the feasibility of initiating treatment with progesterone in a clinical setting in women found to have a short cervix. METHODS: An observational, pragmatic cohort study was conducted at one tertiary care facility from 2012-2015, involving eligible women with singleton pregnancies who accepted and underwent second-trimester CL screening. The primary outcomes were the percentage of women who were eligible and accepting of screening, compliance with progesterone treatment, and the screening value of TVCL in predicting SPTB. Secondary outcomes were the number of women who received progesterone treatment and the rates of SPTB. RESULTS: Overall cervical length screening acceptance rate was found to be 82.5%. Of the 797 women that underwent screening, 21 women (2.6%) had a TVCL < 25 mm, of whom nine had a TVCL < 20.0 mm. Nineteen of the 21 women with a TVCL < 25 mm were treated with progesterone, with a 94.7% compliance rate. Delivery outcomes were obtained for 767 women. Of those with a TVCL < 25 mm, there was a 35% rate of SPTB as opposed to a 6.3% SPTB rate in those with TVCL > 25 mm. The negative predictive value for SPTB with a TVCL 25 mm or greater was 94.0%. CONCLUSION: Universal cervical length screening was successfully implemented in 82.5% of the patient population with a high compliance rate with progesterone treatment. Furthermore, there was a higher rate of SPTB in those with a shorter cervix. Based on our outcomes obtained in an observational and pragmatic manner, we showed that incorporating second trimester transvaginal cervical length screening into routine clinical practice is readily accepted and, with the addition of vaginal progesterone treatment, may reduce the rate of prematurity.


Assuntos
Nascimento Prematuro , Progesterona , Gravidez , Humanos , Feminino , Segundo Trimestre da Gravidez , Progesterona/uso terapêutico , Colo do Útero/diagnóstico por imagem , Nascimento Prematuro/epidemiologia , Estudos de Coortes , Medida do Comprimento Cervical
11.
J Ultrasound Med ; 43(1): 33-43, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37732906

RESUMO

OBJECTIVES: Non-compressive strain elastography has been proposed as a novel quantitative imaging biomarker for assessing the structure and function of the cervix. The current study aims to assess the repeatability, and intra- and inter-observer reliability of transvaginal non-compressive cervical strain elastography in a clinical setting. METHODS: We conducted a dual-phase single-center prospective feasibility study of singleton gestations >16-weeks gestation that required a clinically-indicated transvaginal ultrasound. Each study participant, n = 43 in phase 1 and n = 13 in phase 2, had elastography performed by two trained observers that each performed multiple image acquisitions. We performed a multivariable regression to adjust for changes in clinical characteristics between study phases and calculated the repeatability coefficients, limits of agreement, and intraclass correlations for each quantitative elastography parameter. We compared quantitative elastography parameters to cervical length measurements, acquired from the same images. RESULTS: The repeatability coefficients and percent limits of agreement were wide for all of the quantitative elastography parameters, demonstrating poor repeatability. Intraclass correlation coefficients were poor-moderate for both intra-observer (0.31-0.77) and inter-observer reliability (0.35-0.77) in both study phases, while cervical length showed excellent reliability with intraclass correlations consistently >0.90. CONCLUSIONS: Non-compressive transvaginal strain cervical elastography did not demonstrate adequate repeatability or reliability. Our results highlight the importance of rigorously assessing novel quantitative imaging biomarkers before clinical application.


Assuntos
Colo do Útero , Técnicas de Imagem por Elasticidade , Gravidez , Feminino , Humanos , Colo do Útero/diagnóstico por imagem , Estudos Prospectivos , Técnicas de Imagem por Elasticidade/métodos , Reprodutibilidade dos Testes , Medida do Comprimento Cervical , Variações Dependentes do Observador
12.
Am J Obstet Gynecol ; 230(1): 89.e1-89.e12, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37481152

RESUMO

BACKGROUND: Asymptomatic isthmic contractions are a frequent physiological phenomenon in pregnancy, sometimes triggered by bladder voiding. They can interfere with proper cervical length assessment and may lead to false images of placenta previa. However, there is limited research on the prevalence and characteristics of these contractions. OBJECTIVE: This study aimed to determine the prevalence and characteristics of isthmic contractions after bladder voiding in the second trimester of pregnancy, to evaluate their effect on cervical length assessment, and to propose a new method for the objective assessment of the presence and intensity of isthmic contractions. STUDY DESIGN: In this prospective observational study, long videos of the uterine cervix were recorded in 30 singleton pregnancies during the second trimester of pregnancy after bladder voiding. Isthmic length and cervicoisthmic length changes were assessed over time. The isthmic length was measured using a new approach, which involved calculating the distance from the base of the cervix to the internal os, including the isthmus. RESULTS: Isthmic contractions were observed in 43% of pregnant women (95% confidence interval, 26%-62%) after bladder voiding. The median time for complete isthmus relaxation was 19.7 minutes (95% confidence interval, 15.0 to not available). No substantial differences in maternal characteristics were found between individuals with and without contractions. The proposed method for measuring isthmic length provided an objective assessment of the presence and intensity of isthmic contractions. A cutoff of 18 mm in isthmic length allowed for the distinction of pregnant women presenting a contraction. In addition, the study identified a characteristic undulatory pattern in the relaxation of the isthmus in half of the cases with contractions. CONCLUSION: Isthmic contractions are a common occurrence after bladder voiding in the second trimester of pregnancy and may interfere with proper cervical length assessment. We recommend performing cervical assessment at least 20 minutes after bladder voiding to reduce the risk of bias in cervical length measurement and to avoid false images of placenta previa. The new method for measuring isthmic length provides an objective way to assess the presence and intensity of isthmic contractions. Further research is needed to understand the role of isthmic contractions in the physiology of pregnancy and birth.


Assuntos
Placenta Prévia , Nascimento Prematuro , Gravidez , Feminino , Humanos , Útero/diagnóstico por imagem , Colo do Útero/diagnóstico por imagem , Contração Uterina , Ultrassonografia , Medida do Comprimento Cervical/métodos , Segundo Trimestre da Gravidez , Nascimento Prematuro/epidemiologia
13.
Eur Rev Med Pharmacol Sci ; 27(21): 10221-10232, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37975346

RESUMO

OBJECTIVE: The predictive values of cervix length (CL) measurement based on transvaginal ultrasonography (TVUS) and pathological examination of placenta for premature delivery (PTD) were investigated, and the correlation between PTD and infection was analyzed. PATIENTS AND METHODS: A total of 120 pregnant women with PTD or high-risk factors for PTD admitted to Hengyang Maternal and Child Health Hospital, between February 2020 and March 2022 were included in this retrospective study. There were 36 subjects in the PTD group and 84 in the normal delivery group (control group). They underwent pathological examination of the placenta and TVUS for CL measurement. The final gestational age was set as the standard for the evaluation of the predictive values of pathological examination of the placenta and TVUS. Moreover, a pathological examination of the placenta was used to analyze the correlation between PTD and infection. RESULTS: The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of joint inspection were remarkably superior to those of single CL or pathological examination of the placenta (p<0.05). The proportion of pregnant women with CL ≤30 mm and positive placental pathology was higher than that of pregnant women with CL >30 mm and negative placental pathology (p<0.05). In addition, the incidence of Ureaplasma urealyticum (UU), Chlamydia trachomatis (CT), and chorioamnionitis (CA) in the vaginal discharge of the PTD group was markedly superior to that of the control group (p<0.05). CONCLUSIONS: The combination of CL ≤30 mm and positive placental pathology could effectively predict PTD, and placental infection was notably correlated with the occurrence of PTD.


Assuntos
Trabalho de Parto Prematuro , Nascimento Prematuro , Criança , Feminino , Gravidez , Humanos , Placenta/diagnóstico por imagem , Estudos Retrospectivos , Colo do Útero/diagnóstico por imagem , Nascimento Prematuro/epidemiologia , Medida do Comprimento Cervical , Valor Preditivo dos Testes
14.
Rev Saude Publica ; 57: 87, 2023.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37971181

RESUMO

OBJECTIVE: To perform an economic cost analysis of the implementation of a short cervix screening program to reduce preterm birth in singleton pregnancies in a short-term time horizon. METHODS: We performed a cost-benefit economic analysis using the P5 trial database, a randomized multicenter clinical trial for prevention of preterm birth. Data collection was conducted from July 2015 to March 2019 in 17 different Brazilian hospitals. We conducted a cost analysis for universal cervical screening in singleton pregnancies between 18 weeks and 22 weeks plus 6 days. In subjects with a cervical length ≤ 25 mm, the analysis incorporated the costs of administering 200 mg/day of vaginal progesterone prophylactically until 36 weeks gestation. These findings were subsequently compared with the economic implications of forgoing cervical screening. The time horizon comprised from birth to 10 weeks postpartum. The outcome was measured monetarily in Brazilian real (R$) from the perspective of the Unified Health System. RESULTS: Among 7,844 women, 6.67% (523) had a cervix ≤ 25 mm. The cost of screening with transvaginal ultrasound and vaginal progesterone for prevention of births with < 34 weeks was estimated at R$ 383,711.36, while non-screening generated an estimated additional cost of R$ 446,501.69 (related to the 29 non-screened preterm deliveries). Thus, screening and prophylaxis would generate a final cost reduction of R$ 62,790.33, constituting a possible cost-benefit strategy. CONCLUSION: Universal short cervix screening for preterm birth has lower costs compared to non-screening within a short-term time horizon, which suggests an interesting benefit-cost ratio. Future studies should consider the cost-effectiveness of prophylactic treatment using sensitivity analyses in different scenarios within the Brazilian health system, as well as analyses that consider the long-term costs associated with preterm births, to robustly justify the implementation of a short cervix screening program.


Assuntos
Nascimento Prematuro , Neoplasias do Colo do Útero , Gravidez , Recém-Nascido , Feminino , Humanos , Nascimento Prematuro/prevenção & controle , Progesterona/uso terapêutico , Colo do Útero/diagnóstico por imagem , Detecção Precoce de Câncer , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/prevenção & controle , Medida do Comprimento Cervical , Brasil
15.
J Matern Fetal Neonatal Med ; 36(2): 2262081, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37778754

RESUMO

BACKGROUND: Spontaneous preterm birth occurs more frequently in multiple pregnancies. This syndrome has multiple triggers that result in a unified downstream pathway of cervical remodeling, uterine activity, and progressive cervical dilatation. Whilst the triggers for labor in multiple pregnancy may be different from singletons, the downstream changes will be the same. Identifying patients at risk of preterm birth is a priority as interventions to delay delivery and optimize the fetus can be initiated. Methods for screening for risk of preterm birth which focus on the detection of cervical remodeling may therefore have potential in this population. METHODS: This review explores the evidence for the predictive utility for preterm birth of several published techniques that assess the physical, biomechanical, and optical properties of the cervix, with a focus on those which have been studied in multiple pregnancies and highlighting targets for future research in this population. RESULTS: Fifteen techniques are discussed which assess the physical, biomechanical, and optical properties of the cervix in pregnancy. Of these, only three techniques that evaluated the predictive accuracy of a technique in patients with multiple pregnancies were identified: uterocervical angle, cervical consistency index, and cervical elastography. Of these, measurement of the uterocervical angle has the strongest evidence. Several techniques have shown predictive potential in singleton pregnancies, but have not yet been studied in multiple pregnancies, which would be a logical expansion of research. CONCLUSION: Research on techniques with predictive utility for PTB in patients with multiple pregnancies is limited but should be a research priority. Overall, the theory supports the investigation of cervical remodeling as a predictor of PTB, and there are numerous techniques in development that may have potential in this field.


Assuntos
Nascimento Prematuro , Gravidez , Feminino , Humanos , Recém-Nascido , Nascimento Prematuro/epidemiologia , Colo do Útero/diagnóstico por imagem , Medida do Comprimento Cervical/métodos , Gravidez Múltipla
16.
PLoS One ; 18(10): e0292533, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37797073

RESUMO

BACKGROUND: Shortened cervical length is one of the primary predictors for spontaneous preterm deliveries in twin pregnancies. However, there is lack of consensus regarding cut-off values. Recent evidence highlights that established cut-offs for cervical length screening might not always apply across different populations. This study aims to present the distribution of cervical length in Taiwanese twin pregnancies and to assess its predictive value for spontaneous preterm birth during mid-trimester screening. MATERIALS AND METHODS: This retrospective analysis of cervical length screening in Taiwan evaluated 469 twin pregnancies between 20-24 weeks of gestation. Outcome data were obtained directly from the medical records of the delivery hospital. The study explored the predictive value of cervical length screening for spontaneous preterm birth and the characteristics of cervical length distribution in Taiwanese twin pregnancies. RESULTS: The average gestational age at screening was 22.7 weeks. Cervical length values displayed a non-normal distribution (p-value <0.001). The median, 5th and 95th centiles were 37.5 mm 25.1 mm, and 47.9 mm, respectively. Various cut-off values were assessed using different methods, yielding positive [negative] likelihood ratios for spontaneous preterm births between 32-37 weeks of gestational age (GA) (1.3-30.1 and [0.51-0.92]) and for very preterm births between 28-32 weeks GA (5.6-51.1 and [0.45-0.64]). CONCLUSIONS: The findings from our analysis of Taiwanese twin pregnancies uphold the moderate predictive potential of cervical length screening, consistent with prior investigations. The presented likelihood ratios for predicting preterm birth at different gestational ages equip clinicians with valuable tools to enhance their diagnostic rationale and resource utilization. By fine-tuning screening parameters according to the spontaneous preterm birth prevalence and clinical priorities of the particular population, healthcare providers can enhance patient care. Our data implies that a cervical length below 20 mm might provide an optimal balance between minimizing false negatives and managing false positives when predicting spontaneous preterm birth.


Assuntos
Nascimento Prematuro , Recém-Nascido , Gravidez , Feminino , Humanos , Lactente , Nascimento Prematuro/diagnóstico por imagem , Nascimento Prematuro/epidemiologia , Gravidez de Gêmeos , Estudos Retrospectivos , Medida do Comprimento Cervical/métodos , Colo do Útero/diagnóstico por imagem , Valor Preditivo dos Testes
17.
J Matern Fetal Neonatal Med ; 36(2): 2266545, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37821354

RESUMO

OBJECTIVE: To evaluate the value of transvaginal ultrasound parameters before and after cerclage in twins in predicting spontaneous preterm birth (sPTB) before 28+0 weeks. METHODS: We retrospectively studied the medical records of twin-pregnant women who underwent ultrasound-indicated cerclage between January 2016 and February 2022 at our hospital. Recorded transvaginal ultrasound images before and after cerclage were reassessed for cervical length (CL), uterocervical angle (UCA), funneling, and sludge. Multivariate logistic and Cox regression analyses were performed to identify the independent risk factors associated with sPTB before 28 weeks. RESULTS: A total of 69 women were included. Among them, 17 women (24.64%) delivered before 28 weeks of age. Regression analysis revealed a significant association of post-cerclage CL, UCA, white blood cell (WBC) count, and gestational age (GA) at cerclage with sPTB before 28 weeks. The area under the curve of these predictors was 0.938 (95% confidence interval, 0.882-0.994; p < .001), with a sensitivity of 88.2%, specificity of 92.3%, positive predictive value of 78.9%, and negative predictive value of 96.0%. Cox analysis showed that post-cerclage UCA was an independent risk factor affecting the cerclage-to-delivery interval (hazard ratios, 1.026; 95% confidence interval (CI), 1.004-1.048; p = .019). CONCLUSIONS: The combination of post-cerclage CL, UCA, WBC count, and GA at cerclage showed good performance in predicting sPTB at <28 weeks in twin pregnancy. Post-cerclage UCA is also associated with pregnancy latency. We found that post-cerclage cervical ultrasound may be useful to predict preterm birth before 28 weeks in twins who undergo ultrasound-indicated cerclage.


Assuntos
Cerclagem Cervical , Colo do Útero , Nascimento Prematuro , Ultrassonografia Pré-Natal , Feminino , Humanos , Recém-Nascido , Gravidez , Medida do Comprimento Cervical , Colo do Útero/diagnóstico por imagem , Colo do Útero/cirurgia , Gravidez de Gêmeos , Nascimento Prematuro/diagnóstico por imagem , Nascimento Prematuro/etiologia , Nascimento Prematuro/prevenção & controle , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos
18.
Artigo em Inglês | MEDLINE | ID: mdl-37708656

RESUMO

OBJECTIVE: Preterm birth, defined as delivery before 37 weeks' gestation, is a major obstetric challenge and is associated with serious long-term complications in those infants that survive. Preventative management includes cervical cerclage, either as an elective procedure or performed following transvaginal ultrasound surveillance and shortening of the cervix (≤25 mm). Significant questions remain regarding the optimal management, target population and technique. Therefore, this study aimed to assess differences in risk factors and pregnancy outcomes for women who received an elective cerclage versus ultrasound surveillance, following one prior premature event (spontaneous preterm birth/second trimester loss). STUDY DESIGN: Women were retrospectively identified from St Thomas's Hospital Preterm Birth Clinical Network Database. Women who had one prior premature event (between 14+0 and 36+6 weeks' gestation) were included and they were separated into those that an elective cerclage and those who underwent ultrasound surveillance to assess differences in demographics, pregnancy risk factors and preterm birth outcomes. We excluded women who received other preventative therapies. We also separately analysed those women who required an ultrasound-indicated cerclage, comparing the differences between women that delivered preterm and term. RESULTS: We collected data from 1077 women who had a prior preterm event. 66 women received an elective cerclage. 11.4% of women who had ultrasound surveillance received an ultrasound indicated cerclage. Women with a prior history of mid-trimester loss, instead of preterm birth, were more likely to receive an elective cerclage. The mean gestational age of delivery was similar between those women who received an elective cerclage and those who had ultrasound surveillance with and without an ultrasound-indicated cerclage (38+1 vs 37+1), however, preterm birth rates <37 weeks' were twice as high in this ultrasound group (OR 2.3 [1.1-4.5], p = 0.02). In those women that do require an ultrasound-indicated cerclage, 50.4% deliver preterm. CONCLUSIONS: In conclusion, this study shows that in women with one prior preterm event, both history-indicated cerclage and ultrasound surveillance are appropriate management options. The majority of women undergoing ultrasound surveillance did not require a cerclage and so avoided the potential perioperative complications of cerclage insertion. However, those that did require an ultrasound-indicated cerclage were at high risk of preterm birth so should be followed up closely to enable adequate preterm birth preparation. Further prospective studies comparing history indicated cerclage and US surveillance in women with one prior preterm event are necessary.


Assuntos
Cerclagem Cervical , Nascimento Prematuro , Recém-Nascido , Gravidez , Feminino , Humanos , Nascimento Prematuro/prevenção & controle , Nascimento Prematuro/epidemiologia , Estudos Retrospectivos , Estudos Prospectivos , Resultado da Gravidez , Cerclagem Cervical/métodos , Colo do Útero/cirurgia , Medida do Comprimento Cervical
19.
Acta Obstet Gynecol Scand ; 102(11): 1541-1548, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37737470

RESUMO

INTRODUCTION: Cervical length measurement using transvaginal sonography at 18+0 -24+0 weeks of gestation is used to identify women at risk of preterm delivery, who may benefit from treatment with progesterone to prevent premature birth. Few and conflicting data exist regarding the predictive value of cervical length measurement performed at later gestational ages. The primary objective of this study was to evaluate the predictive accuracy for spontaneous preterm birth of a single cervical length measurement performed between 24 and 32 weeks of gestation in asymptomatic singleton pregnancies at low risk for spontaneous preterm birth. The secondary objective was to test the predictive accuracy of different cervical length thresholds in the same population. MATERIAL AND METHODS: This was a historical cohort study conducted in a tertiary referral hospital. A total of 2728 asymptomatic women with singleton pregnancy at low risk for spontaneous preterm birth were recruited. Of these women, 1548 had cervical length measured at 24+0 -27+6 weeks of gestation and 2191 women at 28+0 -32+0 weeks. In all, 1010 women were present in both gestational age windows. Maternal demographics, medical and obstetrical history, and pregnancy outcome were reviewed. The predictive value of cervical length for spontaneous preterm birth was evaluated through logistic regression analysis. Results were adjusted for confounding factors. RESULTS: Overall, spontaneous preterm birth occurred in 53/2728 women (1.9%). In both the 24+0 -27+6 and 28+0 -32+0 weeks groups, a shorter cervical length was significantly associated with spontaneous preterm birth (p < 0.01), but it had a low predictive value, as shown by the receiver operating characteristics curve analysis (areas under the curve 0.62, 95% CI 0.50-0.74 for the 24+0 -27+6 weeks group, and 0.61, 95% CI 0.52-0.70 in the 28+0 -32+0 weeks group). When the predictive accuracy for preterm delivery of different cervical length cut-offs was evaluated, the sensitivity and positive predictive value were low in both gestational age windows, irrespective of the threshold used. CONCLUSIONS: In asymptomatic women with singleton pregnancy at low risk for spontaneous preterm birth, the predictive value of cervical length after 24+0 weeks of gestation is low. Therefore, cervical length screening in these women should be discouraged.


Assuntos
Nascimento Prematuro , Recém-Nascido , Gravidez , Feminino , Humanos , Nascimento Prematuro/diagnóstico , Nascimento Prematuro/prevenção & controle , Estudos de Coortes , Colo do Útero/diagnóstico por imagem , Resultado da Gravidez , Medida do Comprimento Cervical/métodos
20.
J Matern Fetal Neonatal Med ; 36(2): 2241100, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37518185

RESUMO

OBJECTIVE: The objective of this study is to create a new screening for spontaneous preterm birth (sPTB) based on artificial intelligence (AI). METHODS: This study included 524 singleton pregnancies from 18th to 24th-week gestation after transvaginal ultrasound cervical length (CL) analyzes for screening sPTB < 35 weeks. AI model was created based on the stacking-based ensemble learning method (SBELM) by the neural network, gathering CL < 25 mm, multivariate unadjusted logistic regression (LR), and the best AI algorithm. Receiver Operating Characteristics (ROC) curve to predict sPTB < 35 weeks and area under the curve (AUC), sensitivity, specificity, accuracy, predictive positive and negative values were performed to evaluate CL < 25 mm, LR, the best algorithms of AI and SBELM. RESULTS: The most relevant variables presented by LR were cervical funneling, index straight CL/internal angle inside the cervix (≤ 0.200), previous PTB < 37 weeks, previous curettage, no antibiotic treatment during pregnancy, and weight (≤ 58 kg), no smoking, and CL < 30.9 mm. Fixing 10% of false positive rate, CL < 25 mm and SBELM present, respectively: AUC of 0.318 and 0.808; sensitivity of 33.3% and 47,3%; specificity of 91.8 and 92.8%; positive predictive value of 23.1 and 32.7%; negative predictive value of 94.9 and 96.0%. This machine learning presented high statistical significance when compared to CL < 25 mm after T-test (p < .00001). CONCLUSION: AI applied to clinical and ultrasonographic variables could be a viable option for screening of sPTB < 35 weeks, improving the performance of short cervix, with a low false-positive rate.


Assuntos
Nascimento Prematuro , Gravidez , Feminino , Recém-Nascido , Humanos , Nascimento Prematuro/diagnóstico , Nascimento Prematuro/prevenção & controle , Inteligência Artificial , Medida do Comprimento Cervical/métodos , Valor Preditivo dos Testes , Curva ROC , Colo do Útero/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...